Rocksolid Light

Welcome to Rocksolid Light

mail  files  register  newsreader  groups  login

Message-ID:  

Economics is extremely useful as a form of employment for economists. -- John Kenneth Galbraith


tech / sci.electronics.repair / Hisense AP10CR2W Portable Air Conditioner Issue

SubjectAuthor
* Hisense AP10CR2W Portable Air Conditioner Issuejaugustine
`* Hisense AP10CR2W Portable Air Conditioner Issuehubops
 `* Hisense AP10CR2W Portable Air Conditioner Issuejaugustine
  `* Hisense AP10CR2W Portable Air Conditioner Issuehubops
   `* Hisense AP10CR2W Portable Air Conditioner Issuejaugustine
    +- Hisense AP10CR2W Portable Air Conditioner IssueBob F
    `- Hisense AP10CR2W Portable Air Conditioner Issueohg...@gmail.com

1
Hisense AP10CR2W Portable Air Conditioner Issue

<s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4045&group=sci.electronics.repair#4045

  copy link   Newsgroups: sci.electronics.repair
Path: rocksolid2!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: jaugustine@verizon.net
Newsgroups: sci.electronics.repair
Subject: Hisense AP10CR2W Portable Air Conditioner Issue
Date: Sat, 09 Sep 2023 07:29:33 -0400
Organization: A noiseless patient Spider
Lines: 28
Message-ID: <s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="e011f3c910f092823c8943de27d0a3ff";
logging-data="67273"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+8pWxF5o06hOnDsr5aUiMy"
Cancel-Lock: sha1:Xj0npfVjtzc6gFBqDDQRh1rFQRM=
X-Newsreader: Forte Agent 1.92/32.572
 by: jaugustine@verizon.net - Sat, 9 Sep 2023 11:29 UTC

Hi,

I have a Hisense AP10CR2W portable air conditioner that was
in use when I lost power for about 2 minutes. After the power came
on, the air conditioner resumed running.

Now, when I turn off the air conditioner, it does NOT shut off
completely. The displays go off, there is no more cold air coming
out of the unit, but I hear something "running" inside. Now I have
to unplug the power cord to shut it off completely.

Note: This unit is out of warranty. I could not find out if there
is a "RESET" (not the one on power cord plug) procedure. I could
not find a "Reset" button..

A google search was unsuccessful. One place said to hold the
Fan and Mode buttons for a few seconds. It did NOT work, Another
place said to remove the front panel in order to access a Reset
button, but did not indicate the model number. I did not try that yet.

Hisense's web site, Support, Contact Us, gave me a toll free
telephone number, but that was NO help since if applied to
units under warranty.

Does anyone know a Reset procedure for this model?

Thank You in advance, John

Re: Hisense AP10CR2W Portable Air Conditioner Issue

<hjtofi9i5g1qjbcjl59cffbpeqk28covkn@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4046&group=sci.electronics.repair#4046

  copy link   Newsgroups: sci.electronics.repair
Path: rocksolid2!i2pn.org!weretis.net!feeder6.news.weretis.net!1.us.feeder.erje.net!3.us.feeder.erje.net!feeder.erje.net!usenet.blueworldhosting.com!diablo1.usenet.blueworldhosting.com!peer02.iad!feed-me.highwinds-media.com!news.highwinds-media.com!fx13.iad.POSTED!not-for-mail
From: hubops@ccanoemail.com
Newsgroups: sci.electronics.repair
Subject: Re: Hisense AP10CR2W Portable Air Conditioner Issue
Message-ID: <hjtofi9i5g1qjbcjl59cffbpeqk28covkn@4ax.com>
References: <s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com>
User-Agent: ForteAgent/8.00.32.1272
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Lines: 38
X-Complaints-To: https://www.astraweb.com/aup
NNTP-Posting-Date: Sat, 09 Sep 2023 13:45:56 UTC
Date: Sat, 09 Sep 2023 09:46:00 -0400
X-Received-Bytes: 2100
 by: hubops@ccanoemail.com - Sat, 9 Sep 2023 13:46 UTC

On Sat, 09 Sep 2023 07:29:33 -0400, jaugustine@verizon.net wrote:

>Hi,
>
> I have a Hisense AP10CR2W portable air conditioner that was
>in use when I lost power for about 2 minutes. After the power came
>on, the air conditioner resumed running.
>
> Now, when I turn off the air conditioner, it does NOT shut off
>completely. The displays go off, there is no more cold air coming
>out of the unit, but I hear something "running" inside. Now I have
>to unplug the power cord to shut it off completely.
>
> Note: This unit is out of warranty. I could not find out if there
>is a "RESET" (not the one on power cord plug) procedure. I could
>not find a "Reset" button..
>
> A google search was unsuccessful. One place said to hold the
>Fan and Mode buttons for a few seconds. It did NOT work, Another
>place said to remove the front panel in order to access a Reset
>button, but did not indicate the model number. I did not try that yet.
>
> Hisense's web site, Support, Contact Us, gave me a toll free
>telephone number, but that was NO help since if applied to
>units under warranty.
>
> Does anyone know a Reset procedure for this model?
>
> Thank You in advance, John

Sorry I can't offer any specific advice, but a google search for
portable air conditioner reset
returns some hits that indicate that un-plugging and
leaving it unplugged for an extended time < 30 minutes >
should reset it.
Good luck.
John T.

Re: Hisense AP10CR2W Portable Air Conditioner Issue

<ladpfit34i11j4rm2o4f02vkggb8oe2qt0@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4047&group=sci.electronics.repair#4047

  copy link   Newsgroups: sci.electronics.repair
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: jaugustine@verizon.net
Newsgroups: sci.electronics.repair
Subject: Re: Hisense AP10CR2W Portable Air Conditioner Issue
Date: Sat, 09 Sep 2023 14:21:19 -0400
Organization: A noiseless patient Spider
Lines: 26
Message-ID: <ladpfit34i11j4rm2o4f02vkggb8oe2qt0@4ax.com>
References: <s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com> <hjtofi9i5g1qjbcjl59cffbpeqk28covkn@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="e011f3c910f092823c8943de27d0a3ff";
logging-data="195357"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+L4Bilt0McjiXw5G2vlodl"
Cancel-Lock: sha1:QV8bOiwAm5vE9ArcXHMN7GScDY8=
X-Newsreader: Forte Agent 1.92/32.572
 by: jaugustine@verizon.net - Sat, 9 Sep 2023 18:21 UTC

<SNIP>
>
> Sorry I can't offer any specific advice, but a google search for
> portable air conditioner reset
> returns some hits that indicate that un-plugging and
>leaving it unplugged for an extended time < 30 minutes >
>should reset it.
> Good luck.
> John T.

Hi John T,

For many devices, unplugging for a while does act like a reset, but
not in this case. I had it unplugged for over 24 hours, but that did NOT
resolve the issue.

I could NOT find a Service Manual (PDF file) for this unit via google
search.

I wonder if a relay is "stuck" (contacts "fused" together) ?

Maybe, as a last resort, I will have to open up the unit, However,
I can still use it as long as I unplug it after I turn it off.

John

Re: Hisense AP10CR2W Portable Air Conditioner Issue

<dejpfi5d0qlmt9knbchr1n2056gmf4n15r@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4048&group=sci.electronics.repair#4048

  copy link   Newsgroups: sci.electronics.repair
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!diablo1.usenet.blueworldhosting.com!peer03.iad!feed-me.highwinds-media.com!news.highwinds-media.com!fx38.iad.POSTED!not-for-mail
From: hubops@ccanoemail.com
Newsgroups: sci.electronics.repair
Subject: Re: Hisense AP10CR2W Portable Air Conditioner Issue
Message-ID: <dejpfi5d0qlmt9knbchr1n2056gmf4n15r@4ax.com>
References: <s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com> <hjtofi9i5g1qjbcjl59cffbpeqk28covkn@4ax.com> <ladpfit34i11j4rm2o4f02vkggb8oe2qt0@4ax.com>
User-Agent: ForteAgent/8.00.32.1272
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Lines: 29
X-Complaints-To: https://www.astraweb.com/aup
NNTP-Posting-Date: Sat, 09 Sep 2023 20:18:54 UTC
Date: Sat, 09 Sep 2023 16:18:59 -0400
X-Received-Bytes: 1785
 by: hubops@ccanoemail.com - Sat, 9 Sep 2023 20:18 UTC

On Sat, 09 Sep 2023 14:21:19 -0400, jaugustine@verizon.net wrote:

><SNIP>
>>
>> Sorry I can't offer any specific advice, but a google search for
>> portable air conditioner reset
>> returns some hits that indicate that un-plugging and
>>leaving it unplugged for an extended time < 30 minutes >
>>should reset it.
>> Good luck.
>> John T.
>
>Hi John T,
> For many devices, unplugging for a while does act like a reset, but
>not in this case. I had it unplugged for over 24 hours, but that did NOT
>resolve the issue.
> I could NOT find a Service Manual (PDF file) for this unit via google
>search.
> I wonder if a relay is "stuck" (contacts "fused" together) ?
> Maybe, as a last resort, I will have to open up the unit, However,
>I can still use it as long as I unplug it after I turn it off.
> John
>

One other long-shot - with the device unplugged - press the
power button several times. This is sometimes suggested when
takng apart devices to discharge capacitors.
Is there a reset on the power cord plug ? Try resetting it.
John T.

Re: Hisense AP10CR2W Portable Air Conditioner Issue

<gqspfipclbib107bn71gsdfan6vdtpfmhd@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4049&group=sci.electronics.repair#4049

  copy link   Newsgroups: sci.electronics.repair
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: jaugustine@verizon.net
Newsgroups: sci.electronics.repair
Subject: Re: Hisense AP10CR2W Portable Air Conditioner Issue
Date: Sat, 09 Sep 2023 18:42:50 -0400
Organization: A noiseless patient Spider
Lines: 41
Message-ID: <gqspfipclbib107bn71gsdfan6vdtpfmhd@4ax.com>
References: <s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com> <hjtofi9i5g1qjbcjl59cffbpeqk28covkn@4ax.com> <ladpfit34i11j4rm2o4f02vkggb8oe2qt0@4ax.com> <dejpfi5d0qlmt9knbchr1n2056gmf4n15r@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="0fb68f9aa7606084302aa29238416ea9";
logging-data="264708"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX19pLbnCsmpwarUFrPbfg00G"
Cancel-Lock: sha1:qsig6kCZ9cvGnCWR1KVBM+TqW10=
X-Newsreader: Forte Agent 1.92/32.572
 by: jaugustine@verizon.net - Sat, 9 Sep 2023 22:42 UTC

>><SNIP>
>>>
>>> Sorry I can't offer any specific advice, but a google search for
>>> portable air conditioner reset
>>> returns some hits that indicate that un-plugging and
>>>leaving it unplugged for an extended time < 30 minutes >
>>>should reset it.
>>> Good luck.
>>> John T.
>>
>>Hi John T,
>> For many devices, unplugging for a while does act like a reset, but
>>not in this case. I had it unplugged for over 24 hours, but that did NOT
>>resolve the issue.
>> I could NOT find a Service Manual (PDF file) for this unit via google
>>search.
>> I wonder if a relay is "stuck" (contacts "fused" together) ?
>> Maybe, as a last resort, I will have to open up the unit, However,
>>I can still use it as long as I unplug it after I turn it off.
>> John
>>
>
>One other long-shot - with the device unplugged - press the
>power button several times. This is sometimes suggested when
>takng apart devices to discharge capacitors.
> Is there a reset on the power cord plug ? Try resetting it.
> John T.

UPDATE, ISSUE "WENT AWAY":

My Wife plugged in the air conditioner and turned it on. Later,
she turned if off, but this time, it turned off COMPLETELY !!
The power cord was NOT unplugged.

After about 15 minutes, I decided to try it out. Air ran for a half
hour. When I turned it off, it turned off completely.

Power cord does NOT have to be unplugged anymore.

John

Re: Hisense AP10CR2W Portable Air Conditioner Issue

<udjfip$eora$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4050&group=sci.electronics.repair#4050

  copy link   Newsgroups: sci.electronics.repair
Path: i2pn2.org!rocksolid2!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: bobnospam@gmail.com (Bob F)
Newsgroups: sci.electronics.repair
Subject: Re: Hisense AP10CR2W Portable Air Conditioner Issue
Date: Sat, 9 Sep 2023 21:08:14 -0700
Organization: A noiseless patient Spider
Lines: 44
Message-ID: <udjfip$eora$1@dont-email.me>
References: <s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com>
<hjtofi9i5g1qjbcjl59cffbpeqk28covkn@4ax.com>
<ladpfit34i11j4rm2o4f02vkggb8oe2qt0@4ax.com>
<dejpfi5d0qlmt9knbchr1n2056gmf4n15r@4ax.com>
<gqspfipclbib107bn71gsdfan6vdtpfmhd@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Date: Sun, 10 Sep 2023 04:10:01 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="3c48eb68d91b3400d35a6d6242a5dd03";
logging-data="484202"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX18g8nxM6FFw1A+afUSHmO/O"
User-Agent: Mozilla/5.0 (Windows NT 6.1; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.14.0
Cancel-Lock: sha1:XqbRNIdr5irzJhP91tbd/VjVOM0=
In-Reply-To: <gqspfipclbib107bn71gsdfan6vdtpfmhd@4ax.com>
Content-Language: en-US
 by: Bob F - Sun, 10 Sep 2023 04:08 UTC

On 9/9/2023 3:42 PM, jaugustine@verizon.net wrote:
>>> <SNIP>
>>>>
>>>> Sorry I can't offer any specific advice, but a google search for
>>>> portable air conditioner reset
>>>> returns some hits that indicate that un-plugging and
>>>> leaving it unplugged for an extended time < 30 minutes >
>>>> should reset it.
>>>> Good luck.
>>>> John T.
>>>
>>> Hi John T,
>>> For many devices, unplugging for a while does act like a reset, but
>>> not in this case. I had it unplugged for over 24 hours, but that did NOT
>>> resolve the issue.
>>> I could NOT find a Service Manual (PDF file) for this unit via google
>>> search.
>>> I wonder if a relay is "stuck" (contacts "fused" together) ?
>>> Maybe, as a last resort, I will have to open up the unit, However,
>>> I can still use it as long as I unplug it after I turn it off.
>>> John
>>>
>>
>> One other long-shot - with the device unplugged - press the
>> power button several times. This is sometimes suggested when
>> takng apart devices to discharge capacitors.
>> Is there a reset on the power cord plug ? Try resetting it.
>> John T.
>
> UPDATE, ISSUE "WENT AWAY":
>
> My Wife plugged in the air conditioner and turned it on. Later,
> she turned if off, but this time, it turned off COMPLETELY !!
> The power cord was NOT unplugged.
>
> After about 15 minutes, I decided to try it out. Air ran for a half
> hour. When I turned it off, it turned off completely.
>
> Power cord does NOT have to be unplugged anymore.
>
> John
>

The confessions of a true do it yourselfer. Good job!

Re: Hisense AP10CR2W Portable Air Conditioner Issue

<73f1524c-52e5-4cd2-9c94-515d37444470n@googlegroups.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4073&group=sci.electronics.repair#4073

  copy link   Newsgroups: sci.electronics.repair
X-Received: by 2002:ac8:7dc6:0:b0:415:2360:d099 with SMTP id c6-20020ac87dc6000000b004152360d099mr140263qte.12.1694711523759;
Thu, 14 Sep 2023 10:12:03 -0700 (PDT)
X-Received: by 2002:a4a:37c1:0:b0:573:3e63:3513 with SMTP id
r184-20020a4a37c1000000b005733e633513mr2021922oor.1.1694711523395; Thu, 14
Sep 2023 10:12:03 -0700 (PDT)
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!diablo1.usenet.blueworldhosting.com!peer01.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.repair
Date: Thu, 14 Sep 2023 10:12:02 -0700 (PDT)
In-Reply-To: <gqspfipclbib107bn71gsdfan6vdtpfmhd@4ax.com>
Injection-Info: google-groups.googlegroups.com; posting-host=32.214.221.54; posting-account=caBTYgkAAAA2FIlDBLz82EvvBnsiZ-V4
NNTP-Posting-Host: 32.214.221.54
References: <s9kofip7brj0mda20j7l7uln63r9o04h49@4ax.com> <hjtofi9i5g1qjbcjl59cffbpeqk28covkn@4ax.com>
<ladpfit34i11j4rm2o4f02vkggb8oe2qt0@4ax.com> <dejpfi5d0qlmt9knbchr1n2056gmf4n15r@4ax.com>
<gqspfipclbib107bn71gsdfan6vdtpfmhd@4ax.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <73f1524c-52e5-4cd2-9c94-515d37444470n@googlegroups.com>
Subject: Re: Hisense AP10CR2W Portable Air Conditioner Issue
From: ohger1s@gmail.com (ohg...@gmail.com)
Injection-Date: Thu, 14 Sep 2023 17:12:03 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
X-Received-Bytes: 3336
 by: ohg...@gmail.com - Thu, 14 Sep 2023 17:12 UTC

On Saturday, September 9, 2023 at 6:43:07 PM UTC-4, jaugu...@verizon.net wrote:
> >><SNIP>
> >>>
> >>> Sorry I can't offer any specific advice, but a google search for
> >>> portable air conditioner reset
> >>> returns some hits that indicate that un-plugging and
> >>>leaving it unplugged for an extended time < 30 minutes >
> >>>should reset it.
> >>> Good luck.
> >>> John T.
> >>
> >>Hi John T,
> >> For many devices, unplugging for a while does act like a reset, but
> >>not in this case. I had it unplugged for over 24 hours, but that did NOT
> >>resolve the issue.
> >> I could NOT find a Service Manual (PDF file) for this unit via google
> >>search.
> >> I wonder if a relay is "stuck" (contacts "fused" together) ?
> >> Maybe, as a last resort, I will have to open up the unit, However,
> >>I can still use it as long as I unplug it after I turn it off.
> >> John
> >>
> >
> >One other long-shot - with the device unplugged - press the
> >power button several times. This is sometimes suggested when
> >takng apart devices to discharge capacitors.
> > Is there a reset on the power cord plug ? Try resetting it.
> > John T.
> UPDATE, ISSUE "WENT AWAY":
>
> My Wife plugged in the air conditioner and turned it on. Later,
> she turned if off, but this time, it turned off COMPLETELY !!
> The power cord was NOT unplugged.
>
> After about 15 minutes, I decided to try it out. Air ran for a half
> hour. When I turned it off, it turned off completely.
>
> Power cord does NOT have to be unplugged anymore.
>
> John

Could still be a knackered relay. My microwave would keep the magnetron on intermittently after it was shut off (telltale hum). I pulled the cover and whacked the relay which would last a couple of weeks before it would hang again. Once it was replaced, the problem went away.