Rocksolid Light

Welcome to Rocksolid Light

mail  files  register  newsreader  groups  login

Message-ID:  

<chesty> xemacs fixed my flatulence -- From the "XEmacs: Not just an editor" department


tech / sci.electronics.repair / Mechanical damping of panel meters

SubjectAuthor
* Mechanical damping of panel metersAndrew Smallshaw
`- Mechanical damping of panel meterslegg

1
Mechanical damping of panel meters

<slrnuftucu.qhv.andrews@sdf.org>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4054&group=sci.electronics.repair#4054

  copy link   Newsgroups: sci.electronics.repair
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: andrews@sdf.org (Andrew Smallshaw)
Newsgroups: sci.electronics.repair
Subject: Mechanical damping of panel meters
Date: Mon, 11 Sep 2023 11:27:28 -0000 (UTC)
Organization: A noiseless patient Spider
Lines: 23
Message-ID: <slrnuftucu.qhv.andrews@sdf.org>
Injection-Date: Mon, 11 Sep 2023 11:27:28 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="4b3edd4f011d1809f44e24e0cf313d1b";
logging-data="1099829"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+RHR0CwDhPuAZQZeyvvOEW4F2+ucF0QD8="
User-Agent: slrn/1.0.3 (Patched for libcanlock3) (NetBSD)
Cancel-Lock: sha1:BHE/IPIJ411aap3P/+IaNoNynyI=
 by: Andrew Smallshaw - Mon, 11 Sep 2023 11:27 UTC

Hi all

I've recently picked up an old Weir bench PSU and recalibrated it
to within quite sharp tolerances. However, the front panel meter
(switchable between voltage and current, although the schematic
shows it is working as voltmeter in both modes) reads accurately,
but the settling time must be a good 10-15 seconds before it stops
oscillating back and forth.

I haven't got as far as pulling the meter out yet but I expect
obtaining a compatible replacement will be difficult. Looking at
online it seems most practical sources sources address electrical
damping for brief transients in the signal, this is rather the
mechanical side of things. Basic research suggests pneumatic
damping is the usual order of the day but I haven't found anything
relating to actual maintenance and adjustment.

Does anyone have practical experience or is a replacement meter
the usual approach?

--
Andrew Smallshaw
andrews@sdf.org

Re: Mechanical damping of panel meters

<n93ufi1jecebph93qo7nr8mtjbkam07tm8@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4055&group=sci.electronics.repair#4055

  copy link   Newsgroups: sci.electronics.repair
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: legg@nospam.magma.ca (legg)
Newsgroups: sci.electronics.repair
Subject: Re: Mechanical damping of panel meters
Date: Mon, 11 Sep 2023 09:13:45 -0400
Organization: A noiseless patient Spider
Lines: 31
Message-ID: <n93ufi1jecebph93qo7nr8mtjbkam07tm8@4ax.com>
References: <slrnuftucu.qhv.andrews@sdf.org>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="506d08132dbc70b1797b7bdf1695366e";
logging-data="1130960"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+lqhJ7FvAdMxL8ODO7TFts"
Cancel-Lock: sha1:GIAfOfaz3E8BNFVHO1z7gCO5onc=
X-Newsreader: Forte Agent 4.2/32.1118
 by: legg - Mon, 11 Sep 2023 13:13 UTC

On Mon, 11 Sep 2023 11:27:28 -0000 (UTC), Andrew Smallshaw
<andrews@sdf.org> wrote:

>Hi all
>
>I've recently picked up an old Weir bench PSU and recalibrated it
>to within quite sharp tolerances. However, the front panel meter
>(switchable between voltage and current, although the schematic
>shows it is working as voltmeter in both modes) reads accurately,
>but the settling time must be a good 10-15 seconds before it stops
>oscillating back and forth.
>
>I haven't got as far as pulling the meter out yet but I expect
>obtaining a compatible replacement will be difficult. Looking at
>online it seems most practical sources sources address electrical
>damping for brief transients in the signal, this is rather the
>mechanical side of things. Basic research suggests pneumatic
>damping is the usual order of the day but I haven't found anything
>relating to actual maintenance and adjustment.
>
>Does anyone have practical experience or is a replacement meter
>the usual approach?

.. . . . unless the meter is reading a real disturbance . . .

There's probably a failed capacitor inside that needs replacing.
Could even be an electrolytic across the meter terminals.
Most sensitive moving coil meters (<1mA) are pretty much self-
damping and won't require much filtering to average a measurement.

RL