tech / sci.electronics.repair / Re: PSU Ripple

SubjectAuthor
* PSU RippleCursitor Doom
+* Re: PSU Rippleehsjr
|`- Re: PSU RippleCursitor Doom
`* Re: PSU Ripplelegg
 `* Re: PSU RippleCursitor Doom
  `- Re: PSU Ripplelegg

1
PSU Ripple

<d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4821&group=sci.electronics.repair#4821

  copy link   Newsgroups: sci.electronics.repair sci.electronics design
Path: i2pn2.org!i2pn.org!usenet.goja.nl.eu.org!weretis.net!feeder8.news.weretis.net!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: cd@notformail.com (Cursitor Doom)
Newsgroups: sci.electronics.repair,sci.electronics,design
Subject: PSU Ripple
Date: Sun, 10 Mar 2024 13:35:18 +0000
Organization: A noiseless patient Spider
Lines: 17
Message-ID: <d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="2982adc9a211c867e1a7bf94a4046e9a";
logging-data="3145893"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX18r+FpMt02qi/pD/OlydOzFkF5PKjhS+p8="
User-Agent: ForteAgent/8.00.32.1272
Cancel-Lock: sha1:NET+/KWUVbF/KwErBgPnvQqPZQI=
 by: Cursitor Doom - Sun, 10 Mar 2024 13:35 UTC

Returning to this Marconi signal generator which has a lot of ripple
on the (linear) PSU output, I managed to get probes through a barely
accessible crevice and get a couple of screen shots of the rectifier
outputs I'm seeing on the scope.
So there's mains incoming which goes into a toroidal transformer and
thence to the rectifiers. There are two secondary windings on the
transformer and they each get their own bridge rectifier. This is the
waveform that's being applied to the storage caps of the PSU (which
I've disonnected for testing purposes).
The outputs of neither rectifier look at all correct to me. What does
the Panel make of them?

https://disk.yandex.com/i/CP8qRMy-QA-fCg
https://disk.yandex.com/i/ubNazf1pFhuNtg

(probes are on 10x and I did compensate them first)

Re: PSU Ripple

<usksj8$33d0j$1@news.eternal-september.org>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4822&group=sci.electronics.repair#4822

  copy link   Newsgroups: sci.electronics.repair sci.electronics design
Path: i2pn2.org!i2pn.org!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: ehsjr@verizon.net (ehsjr)
Newsgroups: sci.electronics.repair,sci.electronics,design
Subject: Re: PSU Ripple
Date: Sun, 10 Mar 2024 14:02:14 -0400
Organization: A noiseless patient Spider
Lines: 51
Message-ID: <usksj8$33d0j$1@news.eternal-september.org>
References: <d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Date: Sun, 10 Mar 2024 18:02:16 -0000 (UTC)
Injection-Info: news.eternal-september.org; posting-host="f53dc5522d6e7000906e2118cc84b04b";
logging-data="3257363"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX18E4nG1xIPkW1y4OiV+jL7W"
User-Agent: Mozilla Thunderbird
Cancel-Lock: sha1:2xlTjBuWGWO1FZ2mqdAX02biUtk=
In-Reply-To: <d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com>
Content-Language: en-US
 by: ehsjr - Sun, 10 Mar 2024 18:02 UTC

On 3/10/2024 9:35 AM, Cursitor Doom wrote:
> Returning to this Marconi signal generator which has a lot of ripple
> on the (linear) PSU output, I managed to get probes through a barely
> accessible crevice and get a couple of screen shots of the rectifier
> outputs I'm seeing on the scope.
> So there's mains incoming which goes into a toroidal transformer and
> thence to the rectifiers. There are two secondary windings on the
> transformer and they each get their own bridge rectifier. This is the
> waveform that's being applied to the storage caps of the PSU (which
> I've disonnected for testing purposes).
> The outputs of neither rectifier look at all correct to me. What does
> the Panel make of them?
>
>
> https://disk.yandex.com/i/CP8qRMy-QA-fCg
> https://disk.yandex.com/i/ubNazf1pFhuNtg
>
> (probes are on 10x and I did compensate them first)

If we assume that the probe is (one probe and 1 ground
only!) properly connected across the output of 1 bridge
rectifier ONLY and the load is not connected to that
bridge, you should see an almost perfect waveform.
Do a google on bridge rectifier waveform to see what a
perfect waveform looks like. That's a big assumption,
based on your description of the accessibility problem.

Assuming all is well with the measurement technique,
those wave forms are wrong. Both bridges look bad -
replace them.

With the above action in mind, you must disassemble things
enough to replace the bridges --- SO that means you
must have unfetterd access to the bridges before removal
so that you can make measurements and KNOW you have your
probe and ground connected properly. With that much
disassembly you can use your VOM on diode test to check
the bridges.

To me, it really looks like you _MUST_ do the work, even
though it may be a PITA, to verify that those really
are the waveforms and not a measurements error.

I feel the pain! I had to repair a PW1 linear amplifier
that got "eaten" by lightning. To get to the power supply
parts I had to remove over 140 screws one hundred and
forty! just to gain the needed access.

Good luck.
Ed

Re: PSU Ripple

<o4trui5fpdh3f66jr81kujibvikctre9th@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4823&group=sci.electronics.repair#4823

  copy link   Newsgroups: sci.electronics.repair sci.electronics design
Path: i2pn2.org!i2pn.org!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: legg@nospam.magma.ca (legg)
Newsgroups: sci.electronics.repair,sci.electronics,design
Subject: Re: PSU Ripple
Date: Sun, 10 Mar 2024 14:05:52 -0400
Organization: A noiseless patient Spider
Lines: 35
Message-ID: <o4trui5fpdh3f66jr81kujibvikctre9th@4ax.com>
References: <d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="6b3a8df777a17fe1b6174ba9839775e0";
logging-data="3258150"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1/DtbbyMF1dRyLJ9YfKzWaI"
Cancel-Lock: sha1:meEWtkRzSmhN+lsuR3NQXv05wUM=
X-Newsreader: Forte Agent 4.2/32.1118
 by: legg - Sun, 10 Mar 2024 18:05 UTC

On Sun, 10 Mar 2024 13:35:18 +0000, Cursitor Doom <cd@notformail.com>
wrote:

>Returning to this Marconi signal generator which has a lot of ripple
>on the (linear) PSU output, I managed to get probes through a barely
>accessible crevice and get a couple of screen shots of the rectifier
>outputs I'm seeing on the scope.
> So there's mains incoming which goes into a toroidal transformer and
>thence to the rectifiers. There are two secondary windings on the
>transformer and they each get their own bridge rectifier. This is the
>waveform that's being applied to the storage caps of the PSU (which
>I've disonnected for testing purposes).
>The outputs of neither rectifier look at all correct to me. What does
>the Panel make of them?
>
>
>https://disk.yandex.com/i/CP8qRMy-QA-fCg
>https://disk.yandex.com/i/ubNazf1pFhuNtg
>
>(probes are on 10x and I did compensate them first)

Glad to see you tackling something fairly basic, sport.

Care to mark up your images to include a 0V baseline?

With the bulk caps removed, I trust you are not applying
full mains voltage - just enough to get a diagnostic waveform,
with a load resistor in place.There will be other cicuitry
going bonkers, if not.

Most technicians in this situation will just check/replace
the bridges. If that doesn't do the job, only then is it time
to speculate.

RL

Re: PSU Ripple

<afhsui1f0is8vj6uiv31dcagb1kmfshmnb@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4824&group=sci.electronics.repair#4824

  copy link   Newsgroups: sci.electronics.repair sci.electronics design
Path: i2pn2.org!i2pn.org!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: cd@notformail.com (Cursitor Doom)
Newsgroups: sci.electronics.repair,sci.electronics,design
Subject: Re: PSU Ripple
Date: Sun, 10 Mar 2024 23:51:43 +0000
Organization: A noiseless patient Spider
Lines: 50
Message-ID: <afhsui1f0is8vj6uiv31dcagb1kmfshmnb@4ax.com>
References: <d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com> <o4trui5fpdh3f66jr81kujibvikctre9th@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="842509ddb5b6262d421e7f39189230a8";
logging-data="3399250"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1/1V4NH9o30hbGE01+M3mh/zRHxRvxL2m0="
User-Agent: ForteAgent/8.00.32.1272
Cancel-Lock: sha1:VmTJWGus+F/07OQXP6P+BceN9RE=
 by: Cursitor Doom - Sun, 10 Mar 2024 23:51 UTC

On Sun, 10 Mar 2024 14:05:52 -0400, legg <legg@nospam.magma.ca> wrote:

>On Sun, 10 Mar 2024 13:35:18 +0000, Cursitor Doom <cd@notformail.com>
>wrote:
>
>>Returning to this Marconi signal generator which has a lot of ripple
>>on the (linear) PSU output, I managed to get probes through a barely
>>accessible crevice and get a couple of screen shots of the rectifier
>>outputs I'm seeing on the scope.
>> So there's mains incoming which goes into a toroidal transformer and
>>thence to the rectifiers. There are two secondary windings on the
>>transformer and they each get their own bridge rectifier. This is the
>>waveform that's being applied to the storage caps of the PSU (which
>>I've disonnected for testing purposes).
>>The outputs of neither rectifier look at all correct to me. What does
>>the Panel make of them?
>>
>>
>>https://disk.yandex.com/i/CP8qRMy-QA-fCg
>>https://disk.yandex.com/i/ubNazf1pFhuNtg
>>
>>(probes are on 10x and I did compensate them first)
>
>Glad to see you tackling something fairly basic, sport.

It *would* be extremely basic, if only the manufacturers hadn't gone
out of their way to make these parts as inaccessible as possible.

>
>Care to mark up your images to include a 0V baseline?

I'm only measuring the voltage difference across the bridge output.

>With the bulk caps removed, I trust you are not applying
>full mains voltage - just enough to get a diagnostic waveform,
>with a load resistor in place.There will be other cicuitry
>going bonkers, if not.

Everything downstream has been disconnected. It doesn't seem right
that I'm only seeing 4V peak to peak, though - and that's at the full
230VAC in. The storage caps that waveform is applied to are only rated
at 16VDC, but even so, with no load other than the probe itself, 4V
ain't much.

>Most technicians in this situation will just check/replace
>the bridges. If that doesn't do the job, only then is it time
>to speculate.

Oh yes. I wouldn't have even bothered to query the waveforms I'm
seeing if only the damn rectifiers were readily accessible.

Re: PSU Ripple

<rshsui9f4fug42395b5hau6a8bjoh9vpg2@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4825&group=sci.electronics.repair#4825

  copy link   Newsgroups: sci.electronics.repair
Path: i2pn2.org!i2pn.org!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: cd@notformail.com (Cursitor Doom)
Newsgroups: sci.electronics.repair
Subject: Re: PSU Ripple
Date: Sun, 10 Mar 2024 23:57:47 +0000
Organization: A noiseless patient Spider
Lines: 56
Message-ID: <rshsui9f4fug42395b5hau6a8bjoh9vpg2@4ax.com>
References: <d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com> <usksj8$33d0j$1@news.eternal-september.org>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="842509ddb5b6262d421e7f39189230a8";
logging-data="3400823"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+g+7pgkZ/39WlQO6XV14k3N9cC3JgHo3s="
User-Agent: ForteAgent/8.00.32.1272
Cancel-Lock: sha1:bTT5y8SwsDAgbu0Ve+4VPGpGGQ8=
 by: Cursitor Doom - Sun, 10 Mar 2024 23:57 UTC

On Sun, 10 Mar 2024 14:02:14 -0400, ehsjr <ehsjr@verizon.net> wrote:

>On 3/10/2024 9:35 AM, Cursitor Doom wrote:
>> Returning to this Marconi signal generator which has a lot of ripple
>> on the (linear) PSU output, I managed to get probes through a barely
>> accessible crevice and get a couple of screen shots of the rectifier
>> outputs I'm seeing on the scope.
>> So there's mains incoming which goes into a toroidal transformer and
>> thence to the rectifiers. There are two secondary windings on the
>> transformer and they each get their own bridge rectifier. This is the
>> waveform that's being applied to the storage caps of the PSU (which
>> I've disonnected for testing purposes).
>> The outputs of neither rectifier look at all correct to me. What does
>> the Panel make of them?
>>
>>
>> https://disk.yandex.com/i/CP8qRMy-QA-fCg
>> https://disk.yandex.com/i/ubNazf1pFhuNtg
>>
>> (probes are on 10x and I did compensate them first)
>
>If we assume that the probe is (one probe and 1 ground
>only!) properly connected across the output of 1 bridge
>rectifier ONLY and the load is not connected to that
>bridge, you should see an almost perfect waveform.

Quite. And that *is* how I've measured it.

>Do a google on bridge rectifier waveform to see what a
>perfect waveform looks like. That's a big assumption,
>based on your description of the accessibility problem.

I know what a full-wave rectified signal should look like and what I'm
seeing doesn't much look like one! It does look like a diode's gone
down in each bridge, but it could conceivably be just one that's
failed in certain circumstances I guess.

>Assuming all is well with the measurement technique,
>those wave forms are wrong. Both bridges look bad -
>replace them.
>
>With the above action in mind, you must disassemble things
>enough to replace the bridges --- SO that means you
>must have unfetterd access to the bridges before removal
>so that you can make measurements and KNOW you have your
>probe and ground connected properly. With that much
>disassembly you can use your VOM on diode test to check
>the bridges.
>
>To me, it really looks like you _MUST_ do the work, even
>though it may be a PITA, to verify that those really
>are the waveforms and not a measurements error.

I fully agree. It's just a nuisance not having two consecutive hours
to get stuck into this job. I'm lucking if I can find a spare hour
once a week to work on it. :(

Re: PSU Ripple

<5glsuido8a469guf6ic60pgiifijftnrgl@4ax.com>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=4826&group=sci.electronics.repair#4826

  copy link   Newsgroups: sci.electronics.repair sci.electronics design
Path: i2pn2.org!i2pn.org!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: legg@nospam.magma.ca (legg)
Newsgroups: sci.electronics.repair,sci.electronics,design
Subject: Re: PSU Ripple
Date: Sun, 10 Mar 2024 21:00:03 -0400
Organization: A noiseless patient Spider
Lines: 66
Message-ID: <5glsuido8a469guf6ic60pgiifijftnrgl@4ax.com>
References: <d4druilgjgvf9q9pq4li0fpbu1e54k9rr6@4ax.com> <o4trui5fpdh3f66jr81kujibvikctre9th@4ax.com> <afhsui1f0is8vj6uiv31dcagb1kmfshmnb@4ax.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Injection-Info: dont-email.me; posting-host="4bf5ccac6bd891d8f3c037dd4188dedd";
logging-data="3421867"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX19kgpMqCOLgwYl847F/J/gX"
Cancel-Lock: sha1:teJUBqVwohLurltrBsgDIH9CeXA=
X-Newsreader: Forte Agent 4.2/32.1118
 by: legg - Mon, 11 Mar 2024 01:00 UTC

On Sun, 10 Mar 2024 23:51:43 +0000, Cursitor Doom <cd@notformail.com>
wrote:

>On Sun, 10 Mar 2024 14:05:52 -0400, legg <legg@nospam.magma.ca> wrote:
>
>>On Sun, 10 Mar 2024 13:35:18 +0000, Cursitor Doom <cd@notformail.com>
>>wrote:
>>
>>>Returning to this Marconi signal generator which has a lot of ripple
>>>on the (linear) PSU output, I managed to get probes through a barely
>>>accessible crevice and get a couple of screen shots of the rectifier
>>>outputs I'm seeing on the scope.
>>> So there's mains incoming which goes into a toroidal transformer and
>>>thence to the rectifiers. There are two secondary windings on the
>>>transformer and they each get their own bridge rectifier. This is the
>>>waveform that's being applied to the storage caps of the PSU (which
>>>I've disonnected for testing purposes).
>>>The outputs of neither rectifier look at all correct to me. What does
>>>the Panel make of them?
>>>
>>>
>>>https://disk.yandex.com/i/CP8qRMy-QA-fCg
>>>https://disk.yandex.com/i/ubNazf1pFhuNtg
>>>
>>>(probes are on 10x and I did compensate them first)
>>
>>Glad to see you tackling something fairly basic, sport.
>
>It *would* be extremely basic, if only the manufacturers hadn't gone
>out of their way to make these parts as inaccessible as possible.
>
>>
>>Care to mark up your images to include a 0V baseline?
>
>I'm only measuring the voltage difference across the bridge output.
>
>>With the bulk caps removed, I trust you are not applying
>>full mains voltage - just enough to get a diagnostic waveform,
>>with a load resistor in place.There will be other cicuitry
>>going bonkers, if not.
>
>Everything downstream has been disconnected. It doesn't seem right
>that I'm only seeing 4V peak to peak, though - and that's at the full
>230VAC in. The storage caps that waveform is applied to are only rated
>at 16VDC, but even so, with no load other than the probe itself, 4V
>ain't much.
>
>>Most technicians in this situation will just check/replace
>>the bridges. If that doesn't do the job, only then is it time
>>to speculate.
>
>Oh yes. I wouldn't have even bothered to query the waveforms I'm
>seeing if only the damn rectifiers were readily accessible.

A linear psu, properly designed, was once considered to be the
last point of failure, except for fuses. Fans were considered
as anathema - they were just not used.

It was with this confidence that the psu could be placed at the
bottom, in the back. First failure mode was predicted to be the
storage capacitors - their mtbf was an order of magnitude
smaller than any other component used.

This isn't the case, today, but your unit has some age to it.

RL

1