OT: I Fixed It With Trash

<u74ham$3p6m0$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7756&group=rec.crafts.metalworking#7756

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: none@none.com99 (Bob La Londe)
Newsgroups: rec.crafts.metalworking
Subject: OT: I Fixed It With Trash
Date: Fri, 23 Jun 2023 09:30:12 -0700
Organization: A noiseless patient Spider
Lines: 95
Message-ID: <u74ham$3p6m0$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Date: Fri, 23 Jun 2023 16:30:15 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="17e624b97a3f56a46c63983662645547";
logging-data="3971776"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX18xE+5UoIDIDyo/i63YO9Y4"
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.12.0
Cancel-Lock: sha1:cOeCYkTQxRAJTDHZ6cCiLnaQ9GY=
X-Antivirus: AVG (VPS 230623-2, 6/23/2023), Outbound message
Content-Language: en-US
X-Antivirus-Status: Clean
 by: Bob La Londe - Fri, 23 Jun 2023 16:30 UTC

Growing up having a country grocery store 60 miles from town we often
couldn't get a professional anything out to fix stuff. On the rare
occasions when we could the mileage charges and extra time cost double
what it would cost in town. Usually more than that because they often
didn't even have the parts.

I learned basic electrical and plumbing at an early age. More a common
sense logic flow approach to problem solving.

My dad made friends with a guy who was in the refrigeration business who
taught him the basics, and then he ordered a mail order refrigeration
course. I read all the books and in my early teens started servicing
our commercial refrigeration equipment. I am not and have never been a
refrigeration technician. It was just another skill and set of
knowledge I learned as a country shade tree mechanic. Like pulling an
an engine or dropping a transmission. In modern days of course all the
EPA regs make it "difficult to self service, but not impossible.

I have a friend who has a refrigeration license as part of his families
corporate business and whenever I tackle a "regulated" part of a project
I invite him over to supervise and buy him a nice lunch anywhere he
likes afterwards. We technically obey the law, recover coolant (I have
a recovery machine and so does he), and couple vacuum pumps and a
recovery tank. When he loans me something like a CO2 tank I return it
full, and when I came across an owner acetylene B bottle I gave it to
him. We take care of each other. Even if we haven't spoken in months.

Five (+) years ago one of the two air conditioners on my house failed.
The compressor locked up, and I called the local Tranedealer thinking
I'd just pay the price and be done with it. The tech they sent out got
it wrong. I knew he had it wrong, so I asked him what it would cost if
he was wrong and I was right. The price he said off the cuff was more
than a complete new heat pump and new air handler. I thanked him and
said I'd let him know.

Of course I started doing some research, and my friend suggested trying
a hard start kit. I tried the hard start kit, and it worked for about
two days.

I was able to find sources for an exact OEM replacement compressor, but
surprisingly expensive. Then I found a warehouse store in Michigan who
was selling some on eBay. Including truck freight it was half the cost
of other sources.

It took me about two weeks from failure to restoration during which I
had curtained off that half of the house so the other AC didn't have to
overwork. I did everything right. I set up a brick pad to setup an
extra tall ladder to hang a come-a-long for the compressor swap. Proper
recovery into a bottle marked with the words BURNOUT and the refrigerant
type. Acid neutralizing flush. Nitrogen flush. (Cheaper than CO2 in
the long run and more in a bottle). A little acid neutralizer in the
new compressor oil just in case. Pulled a vacuum over night. Filled it
up, and started it up. Just to be proactive I installed a new contactor
and a new dual motor capacitor.

Until a couple days ago It ran just fine. It was tripping the
compressor breaker, and it seemed on the surface of it that the
compressor had burned out. I had other more important chores so I
pulled the disconnect and left it until yesterday morning. I started
pulling stuff off to get at things, turned the breaker on, and plugged
the disconnect in with it hot so I could see the moment of failure. It
sounded like the compressor was locked up, but the motor was trying, and
then the breaker tripped. I did it a couple times before I realized the
fan was struggling to start too. It would spin up, but slowly and
didn't seem to reach full speed.

I was not hopeful for an easy solution, but I had a little hope at that
moment. I snapped a picture of the wiring, pulled the wires off the cap
and tried to read it with my old Ideal meter. It didn't make sense. It
was like both internal caps had failed. I've never seen that before.
Usually one side fails (often the fan motor) and the other side is still
good. I wasn't sure I was reading it right or maybe that my meter was
bad. Then I saw the old CAP laying in the dirt between the brick pad
I'd made for a solid lifting base and the foundation of the house. For
the heck of it I read the old CAP and it tested in spec on both sides.
My meter was good and I was reading it right. I pulled the mounting
strap, swapped the CAP for the "trash" one I had just picked out of the
dirt, and the AC unit fired up and ran perfectly when I plugged the
disconnect back in again.

It took me longer to put everything back together than it did to perform
the actual repair.

I literally fixed the unit by picking a piece of trash out of the dirt
and stuffing it in there.

--
Bob La Londe
Proffessional Hack, Hobbyist, Wannabe, Shade Tree, Button Pushing, Not a
real machinist

--
This email has been checked for viruses by AVG antivirus software.
www.avg.com

Re: OT: I Fixed It With Trash

<u756da$3re6o$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7757&group=rec.crafts.metalworking#7757

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: muratlanne@gmail.com (Jim Wilkins)
Newsgroups: rec.crafts.metalworking
Subject: Re: OT: I Fixed It With Trash
Date: Fri, 23 Jun 2023 18:29:56 -0400
Organization: A noiseless patient Spider
Lines: 1
Message-ID: <u756da$3re6o$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain;
format=flowed;
charset="UTF-8";
reply-type=response
Content-Transfer-Encoding: 7bit
Injection-Date: Fri, 23 Jun 2023 22:30:02 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="65cdc852974f9ec291d22d1cdd28474c";
logging-data="4045016"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1860+JfHYOaczd7POKg/vwDz6/nJH+Ei+4="
Cancel-Lock: sha1:aROsPuwq04N9IPIFI8DZvuYPBRs=
X-MimeOLE: Produced By Microsoft MimeOLE V16.4.3505.912
X-Priority: 3
X-Antivirus: AVG (VPS 230623-6, 6/23/2023), Outbound message
Importance: Normal
X-Antivirus-Status: Clean
X-Newsreader: Microsoft Windows Live Mail 16.4.3505.912
X-MSMail-Priority: Normal
In-Reply-To: <u74ham$3p6m0$1@dont-email.me>
 by: Jim Wilkins - Fri, 23 Jun 2023 22:29 UTC

"Bob La Londe" wrote in message news:u74ham$3p6m0$1@dont-email.me...

I literally fixed the unit by picking a piece of trash out of the dirt
and stuffing it in there.

---------------------------
Congrats, you beat the System.

When I worked in the automated test equipment industry I learned how to test
components with a DC power supply. For caps I use a voltage and current
adjustable supply to apply a few milliAmps with the voltage limit set to the
cap rating. The voltage on a good electrolytic will rise steadily and hold
after the current is disconnected, DVMs usually have a 10 MegOhm input
resistance that will slowly discharge the cap. The cheap HF DVM is 1 Meg. A
bad cap will stall at the voltage where its leakage increases. The formula
C=IT/V gives the capacitance when you know the current and time to charge
it. Degraded capacitors are pretty obvious when tested this way, plus
reforming stored ones every few years seems to prolong their life.

This gives simpler methods that do the job but won't identify a marginal cap
as clearly.
https://library.e.abb.com/public/79afb1796ad24a19bf2970771c6892e4/Guide_for_capacitor_reforming_Rev_G.pdf

Be careful to discharge the cap afterwards, and between testing the two
polarities on AC motor caps.

The automated test equipment measured the component to determine if it was
within spec or not. It appears the ones that were slightly below spec went
to Radio Shack and more recently Amazon, at least that's what my testing
showed. Analog Devices sent us op amps that tested well above spec to use in
the production line testers we sold them.

Re: OT: I Fixed It With Trash

<u757su$3rfhe$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7758&group=rec.crafts.metalworking#7758

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: none@none.com99 (Bob La Londe)
Newsgroups: rec.crafts.metalworking
Subject: Re: OT: I Fixed It With Trash
Date: Fri, 23 Jun 2023 15:55:25 -0700
Organization: A noiseless patient Spider
Lines: 52
Message-ID: <u757su$3rfhe$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me> <u756da$3re6o$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 8bit
Injection-Date: Fri, 23 Jun 2023 22:55:26 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="51e314482a7231e764adba4e5da58ab5";
logging-data="4046382"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX188czLT5QCJ8xHhnkvPNPXc"
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.12.0
Cancel-Lock: sha1:irlfZ9Fg5TSP6dUyEoggjMWs0M8=
X-Antivirus-Status: Clean
Content-Language: en-US
In-Reply-To: <u756da$3re6o$1@dont-email.me>
X-Antivirus: AVG (VPS 230623-6, 6/23/2023), Outbound message
 by: Bob La Londe - Fri, 23 Jun 2023 22:55 UTC

On 6/23/2023 3:29 PM, Jim Wilkins wrote:
> "Bob La Londe"  wrote in message news:u74ham$3p6m0$1@dont-email.me...
>
> I literally fixed the unit by picking a piece of trash out of the dirt
> and stuffing it in there.
>
> ---------------------------
> Congrats, you beat the System.
>
> When I worked in the automated test equipment industry I learned how to
> test components with a DC power supply. For caps I use a voltage and
> current adjustable supply to apply a few milliAmps with the voltage
> limit set to the cap rating. The voltage on a good electrolytic will
> rise steadily and hold after the current is disconnected, DVMs usually
> have a 10 MegOhm input resistance that will slowly discharge the cap.
> The cheap HF DVM is 1 Meg. A bad cap will stall at the voltage where its
> leakage increases. The formula C=IT/V gives the capacitance when you
> know the current and time to charge it. Degraded capacitors are pretty
> obvious when tested this way, plus reforming stored ones every few years
> seems to prolong their life.
>
> This gives simpler methods that do the job but won't identify a marginal
> cap as clearly.
> https://library.e.abb.com/public/79afb1796ad24a19bf2970771c6892e4/Guide_for_capacitor_reforming_Rev_G.pdf
>
> Be careful to discharge the cap afterwards, and between testing the two
> polarities on AC motor caps.
>
> The automated test equipment measured the component to determine if it
> was within spec or not. It appears the ones that were slightly below
> spec went to Radio Shack and more recently Amazon, at least that's what
> my testing showed. Analog Devices sent us op amps that tested well above
> spec to use in the production line testers we sold them.
>

The little Ideal meter was a gift from my dad when I started messing
with 3 phase CNC stuff. He thought I might need to be able to read
phase rotation. I have never used it for that. I am aware that running
some types of pumps backwards could destroy them, but a spindle is
faster and easier to check with the poor boy "run it and see" method.

This meter has a CAP test function and it seems to read okay.

--
Bob La Londe
CNC Molds N Stuff

--
This email has been checked for viruses by AVG antivirus software.
www.avg.com

Re: I Fixed It With Trash

<u76mot$3q6r$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7760&group=rec.crafts.metalworking#7760

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: muratlanne@gmail.com (Jim Wilkins)
Newsgroups: rec.crafts.metalworking
Subject: Re: I Fixed It With Trash
Date: Sat, 24 Jun 2023 08:15:18 -0400
Organization: A noiseless patient Spider
Lines: 2
Message-ID: <u76mot$3q6r$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me> <u756da$3re6o$1@dont-email.me> <u757su$3rfhe$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain;
format=flowed;
charset="UTF-8";
reply-type=response
Content-Transfer-Encoding: 7bit
Injection-Date: Sat, 24 Jun 2023 12:15:26 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="eb9f2749eb5b397010180e2fdd858f97";
logging-data="125147"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1/qM/gVpIYmeABrJPU4YXajxYzYL0vGeB0="
Cancel-Lock: sha1:5WVTyo1s6m9h7o9BTe1QW3Ob684=
X-MimeOLE: Produced By Microsoft MimeOLE V16.4.3505.912
In-Reply-To: <u757su$3rfhe$1@dont-email.me>
Importance: Normal
X-Antivirus: AVG (VPS 230623-6, 6/23/2023), Outbound message
X-Priority: 3
X-MSMail-Priority: Normal
X-Antivirus-Status: Clean
X-Newsreader: Microsoft Windows Live Mail 16.4.3505.912
 by: Jim Wilkins - Sat, 24 Jun 2023 12:15 UTC

"Bob La Londe" wrote in message news:u757su$3rfhe$1@dont-email.me...
>
The little Ideal meter was a gift from my dad when I started messing
with 3 phase CNC stuff. He thought I might need to be able to read
phase rotation. I have never used it for that. I am aware that running
some types of pumps backwards could destroy them, but a spindle is
faster and easier to check with the poor boy "run it and see" method.

This meter has a CAP test function and it seems to read okay.
Bob La Londe

---------------------

I looked up this Ideal meter to see how much voltage it applies to the cap,
but it doesn't say.
https://www.elliottelectric.com/Media/61361-IDE-4-0-InstallationSheet.pdf

Hand-held, battery powered meters generally don't apply a high voltage to
the Device Under Test, as it would be dangerous to the user. My high voltage
leakage tester produces the voltage with a hand-cranked generator, which
keeps both your hands occupied and off the test leads. Measuring the
capacitance at low voltage won't detect faults like leakage at a higher
voltage.

An expensive professional high voltage insulation tester:
https://www.zoro.com/aemc-instruments-hand-cranked-megohmmeter-1000vdc-6503/i/G3546541/?utm_source=google&utm_medium=surfaces&utm_campaign=shopping%20feed&utm_content=free%20google%20shopping%20clicks

My cheaper one:
https://www.cncest.com/products/metal-shell-1000v-resistanc-meter-insulation-tester-insulation-resistance-tester-with-handle-shaking-test-of-various-motors?gad=1

By paralleling a DVM it will find capacitor (and motor) insulation breakdown
voltage, though its low output current charges electrolytics very slowly.
The built-in meter measures and displays the ratio of voltage to current
which equals resistance, but not the voltage itself. That's regulated by a
centrifugal slip clutch on the generator.

I was lucky to be out sick the day some recently graduated electrical
engineers tested the phase rotation on a large power supply next to where I
was working. I came back to a black stain on the floor and up the side of
the machine I was building, and never saw them again. It seems they had been
squatting beside the supply, touching the 480V cables to the input
terminals, and one slipped and touched a large DC electrolytic.

Re: I Fixed It With Trash

<u76s66$3pnu$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7762&group=rec.crafts.metalworking#7762

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: lfiskgr@gmail.invalid (Leon Fisk)
Newsgroups: rec.crafts.metalworking
Subject: Re: I Fixed It With Trash
Date: Sat, 24 Jun 2023 09:47:50 -0400
Organization: A noiseless patient Spider
Lines: 25
Message-ID: <u76s66$3pnu$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me>
<u756da$3re6o$1@dont-email.me>
<u757su$3rfhe$1@dont-email.me>
<u76mot$3q6r$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain; charset=US-ASCII
Content-Transfer-Encoding: 7bit
Injection-Date: Sat, 24 Jun 2023 13:47:51 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="4d48ac914cb84c8fc386fb2c94dfe7d1";
logging-data="124670"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+fohz94oPytIlDmRng84B9"
Cancel-Lock: sha1:ef1qg614c6y6UVGKqzdIX++9XKI=
X-Newsreader: Claws Mail 3.19.1 (GTK+ 2.24.33; x86_64-pc-linux-gnu)
 by: Leon Fisk - Sat, 24 Jun 2023 13:47 UTC

On Sat, 24 Jun 2023 08:15:18 -0400
"Jim Wilkins" <muratlanne@gmail.com> wrote:

<snip>
>Hand-held, battery powered meters generally don't apply a high voltage to
>the Device Under Test, as it would be dangerous to the user. My high voltage
>leakage tester produces the voltage with a hand-cranked generator, which
>keeps both your hands occupied and off the test leads. Measuring the
>capacitance at low voltage won't detect faults like leakage at a higher
>voltage.

I managed to talk the company into getting a Sencore Z-Meter many years
ago. Its high voltage was pretty basic, just some presets topping out
at 600v. It could measure inductance too which was harder to
check/measure than capacitance at the time. I found its series
resistance measurement on high value capacitors to be the most helpful.
Something I couldn't really measure with my basic BK Capacitance
Meter...

https://worldradiohistory.com/Archive-Company-Publications/Sencore/Sencore-News-1979-08-Z-Meter.pdf

--
Leon Fisk
Grand Rapids MI

Re: I Fixed It With Trash

<u77507$5df4$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7765&group=rec.crafts.metalworking#7765

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: none@none.com99 (Bob La Londe)
Newsgroups: rec.crafts.metalworking
Subject: Re: I Fixed It With Trash
Date: Sat, 24 Jun 2023 09:18:13 -0700
Organization: A noiseless patient Spider
Lines: 76
Message-ID: <u77507$5df4$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me> <u756da$3re6o$1@dont-email.me>
<u757su$3rfhe$1@dont-email.me> <u76mot$3q6r$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 8bit
Injection-Date: Sat, 24 Jun 2023 16:18:15 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="51e314482a7231e764adba4e5da58ab5";
logging-data="177636"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX195OLTwYI+8iNMJRFYl7MeW"
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.12.0
Cancel-Lock: sha1:Lkj7LTBJhL+Ga8CmbAlBn7WUBnc=
In-Reply-To: <u76mot$3q6r$1@dont-email.me>
X-Antivirus-Status: Clean
X-Antivirus: AVG (VPS 230624-2, 6/24/2023), Outbound message
Content-Language: en-US
 by: Bob La Londe - Sat, 24 Jun 2023 16:18 UTC

On 6/24/2023 5:15 AM, Jim Wilkins wrote:
> "Bob La Londe"  wrote in message news:u757su$3rfhe$1@dont-email.me...
>>
> The little Ideal meter was a gift from my dad when I started messing
> with 3 phase CNC stuff.  He thought I might need to be able to read
> phase rotation.  I have never used it for that.  I am aware that running
> some types of pumps backwards could destroy them, but a spindle is
> faster and easier to check with the poor boy "run it and see" method.
>
> This meter has a CAP test function and it seems to read okay.
> Bob La Londe
>
> ---------------------
>
> I looked up this Ideal meter to see how much voltage it applies to the
> cap, but it doesn't say.
> https://www.elliottelectric.com/Media/61361-IDE-4-0-InstallationSheet.pdf
>
> Hand-held, battery powered meters generally don't apply a high voltage
> to the Device Under Test, as it would be dangerous to the user. My high
> voltage leakage tester produces the voltage with a hand-cranked
> generator, which keeps both your hands occupied and off the test leads.
> Measuring the capacitance at low voltage won't detect faults like
> leakage at a higher voltage.
>
> An expensive professional high voltage insulation tester:
> https://www.zoro.com/aemc-instruments-hand-cranked-megohmmeter-1000vdc-6503/i/G3546541/?utm_source=google&utm_medium=surfaces&utm_campaign=shopping%20feed&utm_content=free%20google%20shopping%20clicks
>
> My cheaper one:
> https://www.cncest.com/products/metal-shell-1000v-resistanc-meter-insulation-tester-insulation-resistance-tester-with-handle-shaking-test-of-various-motors?gad=1
>
> By paralleling a DVM it will find capacitor (and motor) insulation
> breakdown voltage, though its low output current charges electrolytics
> very slowly. The built-in meter measures and displays the ratio of
> voltage to current which equals resistance, but not the voltage itself.
> That's regulated by a centrifugal slip clutch on the generator.
>
> I was lucky to be out sick the day some recently graduated electrical
> engineers tested the phase rotation on a large power supply next to
> where I was working. I came back to a black stain on the floor and up
> the side of the machine I was building, and never saw them again. It
> seems they had been squatting beside the supply, touching the 480V
> cables to the input terminals, and one slipped and touched a large DC
> electrolytic.
>

I think that may be the newer model of the same meter I have.

I spent a couple winters running the hydraulic press in a cotton gin on
the night shift. One day some equipment was down and the head ginner
had me up on one the catwalks assisting. He had one of those little
cheap analog meters we sold in my dad's hardware store and he was
checking fuses with it. 440-480 volt motors (I think) on a machine
called a moss. Basically a giant rotating bin dryer. He had just
checked the the third fuse when I realized the disconnect was not turned
off. Whew! We dodged a bullet there. If one of those fuses had been
bad it would have been bad! Then without switching the meter I saw him
start to put the leads from one fuse to the next. I didn't see him make
contact because I was already facing the other way by then. The
explosion was impressive, but the blue flash reflected off the far walls
lit the gin up like daylight. I turned back to see if he was okay to
see him standing there looking a bit sheepish holding a molten blob up
by one of the leads, and he asked, "Do you think your dad will make good
on this meter."

--
Bob La Londe
Proffessional Hack, Hobbyist, Wannabe, Shade Tree, Button Pushing, Not a
real machinist

--
This email has been checked for viruses by AVG antivirus software.
www.avg.com

Re: I Fixed It With Trash

<u777g3$5l5c$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7766&group=rec.crafts.metalworking#7766

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: muratlanne@gmail.com (Jim Wilkins)
Newsgroups: rec.crafts.metalworking
Subject: Re: I Fixed It With Trash
Date: Sat, 24 Jun 2023 13:00:44 -0400
Organization: A noiseless patient Spider
Lines: 2
Message-ID: <u777g3$5l5c$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me> <u756da$3re6o$1@dont-email.me> <u757su$3rfhe$1@dont-email.me> <u76mot$3q6r$1@dont-email.me> <u77507$5df4$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain;
format=flowed;
charset="UTF-8";
reply-type=response
Content-Transfer-Encoding: 7bit
Injection-Date: Sat, 24 Jun 2023 17:00:51 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="c1c298ee7670e246d6f5e510bfbc93e5";
logging-data="185516"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1/wEcLs9D8sr2sM2V3kaQWLigNsfebBjFc="
Cancel-Lock: sha1:S4cXlDJSK/ctAA+aZEeXpyYGeoE=
In-Reply-To: <u77507$5df4$1@dont-email.me>
Importance: Normal
X-Antivirus-Status: Clean
X-Priority: 3
X-MimeOLE: Produced By Microsoft MimeOLE V16.4.3505.912
X-Newsreader: Microsoft Windows Live Mail 16.4.3505.912
X-MSMail-Priority: Normal
X-Antivirus: AVG (VPS 230624-2, 6/24/2023), Outbound message
 by: Jim Wilkins - Sat, 24 Jun 2023 17:00 UTC

"Bob La Londe" wrote in message news:u77507$5df4$1@dont-email.me...

....The
explosion was impressive, but the blue flash reflected off the far walls
lit the gin up like daylight. I turned back to see if he was okay to
see him standing there looking a bit sheepish holding a molten blob up
by one of the leads, and he asked, "Do you think your dad will make good
on this meter."

Bob La Londe

-----------------------

He was lucky. A tech working close to my bench hooked a scope probe to the
gate of an SCR and the ground to the cathode, not considering that the SCR
was on the hot side with optically isolated control. When he hit the breaker
the probe cable exploded violently enough to send him to the ER, and I never
saw him again to hear about it.

At the same job I happened to be looking at an aluminum-wired breaker panel
about 20 feet away when the door blew off with a loud bang and a big red
flash.

I was the battery tech for an electric car project with a 300V battery that
required some internal testing to be done hot. I'm very happy to have no
"interesting" stories to tell about it.

Re: OT: I Fixed It With Trash

<nUWlM.46476$7915.29737@fx10.iad>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7768&group=rec.crafts.metalworking#7768

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!diablo1.usenet.blueworldhosting.com!peer01.iad!feed-me.highwinds-media.com!news.highwinds-media.com!fx10.iad.POSTED!not-for-mail
Subject: Re: OT: I Fixed It With Trash
Newsgroups: rec.crafts.metalworking
References: <u74ham$3p6m0$1@dont-email.me>
From: BobEngelhardt@comcast.net (Bob Engelhardt)
User-Agent: Mozilla/5.0 (Windows NT 10.0; WOW64; rv:52.0) Gecko/20100101
Thunderbird/52.6.0
MIME-Version: 1.0
In-Reply-To: <u74ham$3p6m0$1@dont-email.me>
Content-Type: text/plain; charset=utf-8; format=flowed
Content-Language: en-US
Content-Transfer-Encoding: 7bit
Lines: 8
Message-ID: <nUWlM.46476$7915.29737@fx10.iad>
X-Complaints-To: https://www.astraweb.com/aup
NNTP-Posting-Date: Sun, 25 Jun 2023 13:01:07 UTC
Date: Sun, 25 Jun 2023 09:01:06 -0400
X-Received-Bytes: 891
 by: Bob Engelhardt - Sun, 25 Jun 2023 13:01 UTC

On 6/23/2023 12:30 PM, Bob La Londe wrote:
[...]
>
Just to be proactive I installed a new contactor
> and a new dual motor capacitor.
> [...]

I hope that you gave the cap supplier an earful!!

Re: I Fixed It With Trash

<u79qe5$hgvu$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7769&group=rec.crafts.metalworking#7769

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: muratlanne@gmail.com (Jim Wilkins)
Newsgroups: rec.crafts.metalworking
Subject: Re: I Fixed It With Trash
Date: Sun, 25 Jun 2023 12:36:14 -0400
Organization: A noiseless patient Spider
Lines: 1
Message-ID: <u79qe5$hgvu$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me> <nUWlM.46476$7915.29737@fx10.iad>
MIME-Version: 1.0
Content-Type: text/plain;
format=flowed;
charset="UTF-8";
reply-type=response
Content-Transfer-Encoding: 7bit
Injection-Date: Sun, 25 Jun 2023 16:36:22 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="3172b82d7cd9c4e2e98eddd918f64558";
logging-data="574462"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX19iuTKOA9eZtJ1qcqD4uuQktqZVNX+H7KM="
Cancel-Lock: sha1:5sgvE0OE3AXsKT6a8OiieVbw7cQ=
Importance: Normal
In-Reply-To: <nUWlM.46476$7915.29737@fx10.iad>
X-MimeOLE: Produced By Microsoft MimeOLE V16.4.3505.912
X-Antivirus: AVG (VPS 230625-2, 6/25/2023), Outbound message
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Windows Live Mail 16.4.3505.912
X-Antivirus-Status: Clean
X-Priority: 3
 by: Jim Wilkins - Sun, 25 Jun 2023 16:36 UTC

"Bob Engelhardt" wrote in message news:nUWlM.46476$7915.29737@fx10.iad...

On 6/23/2023 12:30 PM, Bob La Londe wrote:
[...]
>
Just to be proactive I installed a new contactor
> and a new dual motor capacitor.
> [...]

I hope that you gave the cap supplier an earful!!

------------------------------------

https://www.troublefreepool.com/threads/what-is-the-shelf-life-for-a-run-capacitor.84995/

"The old ones with hazardous chemistry lasted forever, but newer ones don't
last long. I usually wait a year after replacing one and then order another
one to keep on hand."

The hazardous chemicals were preservatives that absorbed hydrogen and
buffered the pH to slightly acidic.

Re: OT: I Fixed It With Trash

<u79sm6$hpmv$1@dont-email.me>

  copy mid

https://news.novabbs.org/tech/article-flat.php?id=7770&group=rec.crafts.metalworking#7770

  copy link   Newsgroups: rec.crafts.metalworking
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: none@none.com99 (Bob La Londe)
Newsgroups: rec.crafts.metalworking
Subject: Re: OT: I Fixed It With Trash
Date: Sun, 25 Jun 2023 10:14:46 -0700
Organization: A noiseless patient Spider
Lines: 21
Message-ID: <u79sm6$hpmv$1@dont-email.me>
References: <u74ham$3p6m0$1@dont-email.me> <nUWlM.46476$7915.29737@fx10.iad>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Date: Sun, 25 Jun 2023 17:14:47 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="11e4355255e2e3d5ea71a40c039e062e";
logging-data="583391"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1/7LEXexYQqvt0DvWOZFcw0"
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.12.0
Cancel-Lock: sha1:URwBfEtNbUvioIjRivmpLsttS94=
Content-Language: en-US
X-Antivirus: AVG (VPS 230625-4, 6/25/2023), Outbound message
In-Reply-To: <nUWlM.46476$7915.29737@fx10.iad>
X-Antivirus-Status: Clean
 by: Bob La Londe - Sun, 25 Jun 2023 17:14 UTC

On 6/25/2023 6:01 AM, Bob Engelhardt wrote:
> On 6/23/2023 12:30 PM, Bob La Londe wrote:
> [...]
>>
> Just to be proactive I installed a new contactor
>> and a new dual motor capacitor.
>> [...]
>
> I hope that you gave the cap supplier an earful!!

I don't even remember where I bought it. Its been a few years.

--
Bob La Londe
CNC Molds N Stuff

--
This email has been checked for viruses by AVG antivirus software.
www.avg.com